Career opportunities
coming soon...
coming soon...
Miviko d.o.o.
Rastovaca bb
88240 Posusje
Bosnia i Herzegovina
Tel: +38739852333
Fax: +38739852334
Ova e-mail adresa je zaštićena od spambota. Potrebno je omogućiti JavaScript da je vidite.
Commercial office
Tel: +38739852340
Fax: +38739852334
Mob: +38763299261
Ova e-mail adresa je zaštićena od spambota. Potrebno je omogućiti JavaScript da je vidite.
Miviko d.o.o.
Rastovaca bb
88240 Posusje
Bosnia and Herzegovina
Tel: +38739852333
Fax: +38739852334
Ova e-mail adresa je zaštićena od spambota. Potrebno je omogućiti JavaScript da je vidite.
Sales
Tel: +38739852340
Fax: +38739852334
Mob: +38763299261
Ova e-mail adresa je zaštićena od spambota. Potrebno je omogućiti JavaScript da je vidite.
Distribution and signal power cable for static outdoor application (with protection against direct UV-irradiation), in ground, within facilities, in cable canals, in concrete, in conditions where heavier mechanical loads and specially tensile strains, are not expected. Used in electric power plants, transformer stations, industrial plants, metropolitan networks and in other electric plants, same as for connection of signalling devices in industry, traffic and similar.
Equivalents:
PP00 acc. to HRN N.C5 220
NYY acc. to DIN VDE 0276-603
Standards:
HRN HD 603 S1
ÖVE-K 603
IEC 60502-1
Nominal voltage: U0/U = 0,6/1 kV
Test voltage: 4 kV
Temperature range:
Minimum temperature during installation: -5° C
Fixed installed: -20° C to +70° C
At short circuit of max. 5s: 160° C
Behaviour in fire:
Flame retardant (self-extinguishing) cable
acc. to EN 60332-1-2
Minimal inner bending radius: 12xØ multi core,
15xØ single core
CONSTRUCTION DATA | ||||||||
Construction |
Shape |
Outer |
Conductor |
Current |
Current |
Cu weight |
Cable |
Packing* |
mm2 | ca. mm | Ω/km | nom.A | nom.A | kg/km | ca. kg/km | ||
1 X 4 | RE | 7,5 | 4,61 | 37 | 50 | 40 | 85 | KOT 100, SP40 500 |
1 X 6 | RE | 8,0 | 3,08 | 47 | 62 | 60 | 111 | KOT 100, SP40 500 |
1 X 10 | RE/RM | 9,3 | 1,83 | 64 | 83 | 100 | 164 | SP45 500 |
1 X 16 | RE/RM | 10,3 | 1,15 | 84 | 107 | 160 | 228 | SP45 500, SP60 500 |
1 X 25 | RM | 12,1 | 0,727 | 114 | 138 | 250 | 336 | SP60 500 |
1 X 35 | RM | 13,2 | 0,524 | 139 | 164 | 350 | 445 | SP60 500 |
1 X 50 | RM | 15,0 | 0,387 | 169 | 195 | 500 | 598 | SP70 500 |
2 X 1,5 | RE | 11,4 | 12,1 | 20 | 27 | 30 | 184 | SP45 500 |
2 X 2,5 | RE | 12,2 | 7,41 | 25 | 36 | 50 | 218 | SP50 500 |
2 X 4 | RE | 13,7 | 4,61 | 34 | 47 | 80 | 300 | SP60 500 |
2 X 6 | RE | 14,7 | 3,08 | 43 | 59 | 120 | 348 | SP60 500 |
3 X 1,5 | RE | 11,8 | 12,1 | 20 | 27 | 45 | 201 | KOT 100, SP50 500 |
3 X 2,5 | RE | 12,7 | 7,41 | 25 | 36 | 75 | 243 | KOT 100, SP50 500 |
3 X 4 | RE | 14,4 | 4,61 | 34 | 47 | 120 | 342 | KOT 100, SP60 500 |
3 X 6 | RE | 15,5 | 3,08 | 43 | 59 | 180 | 425 | SP70 500 |
3 X 10 | RE/RM | 17,2 | 1,83 | 59 | 79 | 300 | 594 | DB08 500 |
3 X 16 | RE/RM | 20,6 | 1,15 | 79 | 102 | 480 | 835 | DB08 500 |
3 X 25 | RM | 24,7 | 0,727 | 106 | 133 | 750 | 1180 | DB10 500 |
3 X 35 | RM | 27,1 | 0,524 | 129 | 159 | 1050 | 1460 | DB10 500 |
4 X 1,5 | RE | 12,6 | 12,1 | 20 | 27 | 60 | 204 | KOT 100, SP50 500 |
4 X 2,5 | RE | 13,5 | 7,41 | 25 | 36 | 100 | 274 | KOT 100, SP60 500 |
4 X 4 | RE | 15,4 | 4,61 | 34 | 47 | 160 | 378 | KOT 100, SP70 500 |
4 X 6 | RE | 16,5 | 3,08 | 43 | 59 | 240 | 482 | DB08 500 |
4 X 10 | RE/RM | 18,8 | 1,83 | 59 | 79 | 400 | 689 | DB08 500 |
4 X 16 | RE/RM | 21,6 | 1,15 | 79 | 102 | 640 | 986 | DB09 500 |
4 X 25 | RM | 27,4 | 0,727 | 106 | 133 | 1000 | 1420 | DB10 500 |
5 X 1,5 | RE | 13,0 | 12,1 | 20 | 27 | 75 | 239 | KOT 100, SP60 500 |
5 X 2,5 | RE | 13,9 | 7,41 | 25 | 36 | 125 | 306 | KOT 100, SP60 500 |
5 X 4 | RE | 16,2 | 4,61 | 34 | 47 | 200 | 418 | DB08 500 |
5 X 6 | RE | 17,7 | 3,08 | 43 | 59 | 300 | 564 | DB09 500 |
5 X 10 | RE/RM | 20,2 | 1,83 | 59 | 79 | 500 | 854 | DB09 500 |
5 X 16 | RE/RM | 25,5 | 1,15 | 79 | 102 | 800 | 1205 | DB10 500 |
(bk) black
* Packing: KOT 100 = coil 100m, SP = cable on plywood reel, DB = cable on wooden drum
Distribution and signal power cable for static application in ground, within facilities, in cable canals, in concrete, where heavier mechanical stresses are not expected, and the cable has to be protected against mechanical damages, also in conditions where cables are not exposed to heavier tensile strains. Used in electric power plants, transformer stations, industrial plants, metropolitan networks and in other electric plants where heavier current and thermal loads are expected (operating temperature of conductor up to 90 °C).
Equivalents::
XP00 acc. to HRN N.C5 230
Cu/XLPE/PVC acc. to BS 5467
Standards:
HRN HD 603 S1
DIN VDE 0276-603
IEC 60502-1
Nominal voltage: U0/U = 0,6/1 kV
Test voltage: 4 kV
Temperature range:
Minimum temperature during installation: -5° C
Fixed installed: -20° C to +90° C
At short circuit of max. 5s: 250° C
Behaviour in fire:
Flame retardant (self-extinguishing) cable
acc. to EN 60332-1-2
Minimal inner bending radius: 12xØ multi core,
15xØ single core
CONSTRUCTION DATA | ||||||||
Construction |
Shape |
Outer |
Conductor |
Current |
Current |
Cu weight |
Cable |
Packing* |
mm2 | ca. mm | Ω/km | nom.A | nom.A | kg/km | ca. kg/km | ||
1 X 10 | RE/RM | 9,3 | 1,83 | 77 | 89 | 96 | 142 | SP40 500 |
1 X 16 | RE/RM | 10,4 | 1,15 | 102 | 115 | 153,6 | 205 | SP45 500 |
1 X 25 | RE | 12,1 | 0,727 | 138 | 148 | 240 | 303 | SP50 500 |
1 X 35 | RE | 13,2 | 0,524 | 170 | 177 | 336 | 394 | SP60 500 |
1 X 50 | RE | 14,8 | 0,387 | 207 | 209 | 480 | 516 | SP60 500 |
2 X 1,5 | RE | 9,5 | 12,1 | 26 | 37 | 28,8 | 126 | SP45 500 |
2 X 2,5 | RE | 10,2 | 7,41 | 36 | 49 | 48 | 157 | SP45 500 |
2 X 4 | RE | 11,4 | 4,61 | 49 | 64 | 76,8 | 200 | SP50 500 |
2 X 6 | RE | 12,4 | 3,08 | 63 | 79 | 115,2 | 253 | SP60 500 |
3 X 1,5 | RE | 9,9 | 12,1 | 24 | 31 | 43,2 | 147 | KOT 100, SP45 500 |
3 X 2,5 | RE | 10,8 | 7,41 | 32 | 40 | 72 | 187 | KOT 100, SP50 500 |
3 X 4 | RE | 12,0 | 4,61 | 42 | 52 | 115,2 | 243 | KOT 100, SP60 500 |
3 X 6 | RE | 13,1 | 3,08 | 53 | 64 | 172,8 | 315 | SP60 500 |
3 X 10 | RE/RM | 16,3 | 1,83 | 74 | 86 | 288 | 495 | DB09 500 |
3 X 16 | RE/RM | 18,5 | 1,15 | 98 | 112 | 460,8 | 712 | DB08 500 |
3 X 25 | RE | 22,7 | 0,727 | 133 | 145 | 720 | 1038 | DB09 500 |
4 X 1,5 | RE | 11,2 | 12,1 | 24 | 31 | 57,6 | 173 | KOT 100, SP50 500 |
4 X 2,5 | RE | 12,2 | 7,41 | 32 | 40 | 96 | 224 | KOT 100, SP50 500 |
4 X 4 | RE | 13,8 | 4,61 | 42 | 52 | 153,6 | 292 | KOT 100, SP60 500 |
4 X 6 | RE | 15,0 | 3,08 | 53 | 64 | 230,4 | 382 | DB08 500 |
4 X 10 | RE/RM | 18,3 | 1,83 | 74 | 86 | 384 | 612 | DB08 500 |
4 X 16 | RE/RM | 21,0 | 1,15 | 98 | 112 | 614,4 | 889 | DB09 500 |
4 X 25 | RE | 27,3 | 0,727 | 133 | 145 | 960 | 1328 | DB10 500 |
5 X 1,5 | RE | 13,3 | 12,1 | 24 | 31 | 72 | 205 | KOT 100, SP50 500 |
5 X 2,5 | RE | 14,3 | 7,41 | 32 | 40 | 120 | 267 | KOT 100, SP60 500 |
5 X 4 | RE | 16,7 | 4,61 | 42 | 52 | 192 | 358 | DB08 500 |
5 X 6 | RE | 18,1 | 3,08 | 53 | 64 | 288 | 471 | DB08 500 |
5 X 10 | RE/RM | 22,4 | 1,83 | 74 | 86 | 480 | 745 | DB08 500 |
5 X 16 | RE/RM | 25,7 | 1,15 | 98 | 112 | 768 | 1066 | DB09 500 |
(bk) black
* Packing: KOT 100 = coil 100m, SP = cable on plywood reel, DB = cable on wooden drum
In dry and damp locations for low and medium-level mechanical stress, but not in the open-air. To be used as a termination and connection cable in the control, measuring and signal technology. Suitable as a signal and impulse cable for control and inspection of industrial plants, production lines and machinery.
Cable type:
YSLY-JZ cores with black figures,
with green/yellow core
YSLY-OZ cores with black figures,
without green/yellow core
YSLY-JB cores in different colours,
with green/yellow core
YSLY-OB cores in different colours,
without green/yellow core
Nominal voltage: U0/U = 300/500 V
Test voltage: 2000 V
Temperature range:
Minimum temperature during installation: -5°C
Fixed installed: -15°C to +70°C
At short circuit of max. 5s: 160°C
Behaviour in fire:
Flame retardant (self-extinguishing) cable
acc. to EN 60332-1-2
Minimal inner bending radius:
fixed installation 4xØ cable,
moved application 15xØ cable
CONSTRUCTION DATA | |||||
Construction |
Outer |
Conductor |
Cu weight |
Cable |
Packing* |
mm2 | ca. mm | Ω/km | kg/km | ca. kg/km | |
2 X 0,5 | 4,8 | 39 | 9,6 | 35 | KOT 100, SP40 500 |
2 X 0,75 | 5,2 | 26 | 14,4 | 42 | KOT 100, SP40 500 |
2 X 1 | 5,6 | 19,5 | 19,2 | 52 | KOT 100, SP40 500 |
2 X 1,5 | 6,4 | 13,3 | 28,8 | 65 | KOT 100, SP40 500 |
2 X 2,5 | 7,6 | 7,98 | 48 | 99 | KOT 100, SP40 500 |
3 X 0,5 | 5,1 | 39 | 14,4 | 41 | KOT 100, SP40 500 |
3 X 0,75 | 5,5 | 26 | 21,6 | 51 | KOT 100, SP40 500 |
3 X 1 | 6,1 | 19,5 | 28,8 | 65 | KOT 100, SP40 500 |
3 X 1,5 | 6,8 | 13,3 | 43,2 | 80 | KOT 100, SP40 500 |
3 X 2,5 | 8,3 | 7,98 | 72 | 128 | KOT 100, SP40 500 |
3 X 4 | 10,0 | 4,95 | 115,2 | 169 | KOT 100, SP45 500 |
3 X 6 | 11,5 | 3,3 | 172,8 | 267 | KOT 100, SP60 500 |
3 X 10 | 15,0 | 1,91 | 288 | 465 | KOT 100, SP70 500 |
4 X 0,5 | 5,5 | 39 | 19,2 | 49 | KOT 100, SP40 500 |
4 X 0,75 | 6,2 | 26 | 28,8 | 63 | KOT 100, SP40 500 |
4 X 1 | 6,7 | 19,5 | 38,4 | 78 | KOT 100, SP40 500 |
4 X 1,5 | 7,6 | 13,3 | 57,6 | 102 | KOT 100, SP40 500 |
4 X 2,5 | 9,0 | 7,98 | 96 | 159 | KOT 100, SP45 500 |
4 X 4 | 11,0 | 4,95 | 153,6 | 242 | KOT 100, SP50 500 |
4 X 6 | 13,0 | 3,3 | 230,4 | 340 | KOT 100, SP60 500 |
4 X 10 | 17,0 | 1,91 | 384 | 577 | KOT 100, SP75 500 |
5 X 0,5 | 6,2 | 39 | 24 | 60 | KOT 100, SP40 500 |
5 X 0,75 | 6,7 | 26 | 36 | 78 | KOT 100, SP40 500 |
5 X 1 | 7,5 | 19,5 | 48 | 95 | KOT 100, SP40 500 |
5 X 1,5 | 8,3 | 13,3 | 72 | 125 | KOT 100, SP40 500 |
5 X 2,5 | 10,1 | 7,98 | 120 | 199 | KOT 100, SP50 500 |
5 X 4 | 12,5 | 4,95 | 192 | 302 | KOT 100, SP60 500 |
5 X 6 | 14,0 | 3,3 | 288 | 424 | KOT 100, SP70 500 |
5 X 10 | 18,5 | 1,91 | 480 | 717 | KOT 100, DB09 500 |
6 X 0,75 | 7,3 | 26 | 43,2 | 85 | KOT 100, SP40 500 |
6 X 1 | 7,9 | 19,5 | 57,6 | 102 | KOT 100, SP40 500 |
6 X 1,5 | 8,5 | 13,3 | 86,4 | 129 | KOT 100, SP45 500 |
7 X 0,5 | 6,7 | 39 | 33,6 | 77 | KOT 100, SP40 500 |
7 X 0,75 | 7,5 | 26 | 50,4 | 95 | KOT 100, SP40 500 |
7 X 1 | 8,1 | 19,5 | 67,2 | 120 | KOT 100, SP40 500 |
7 X 1,5 | 9,2 | 13,3 | 100,8 | 166 | KOT 100, SP45 500 |
7 X 2,5 | 11,2 | 7,98 | 168 | 258 | KOT 100, SP60 500 |
(gy) grey
* Packing: KOT 100 = coil 100m, SP = cable on plywood reel, DB = cable on wooden drum